1,000+ Total Reviews · Performed by PS Specialist · 1 min from Nonhyeon Stn.
Implant

Implant Issues

Implant Side Effects · Trouble

Show-through, contracture, shifting, inflammation, and other implant-related issues — VVLY diagnoses the cause and addresses it, from removal through conversion to autologous tissue.

About Implant Issues

Implant Related Issues

What are implant issues?

Nasal implants (silicone, Gore-Tex, and similar materials) can develop issues over time such as show-through, shifting, contracture, inflammation, and elevation (turning up). These changes can relate to several factors, including skin thickness, implant type, and tissue reaction.

What matters most is accurately identifying the cause of the symptom. In some cases simple repositioning is enough; in others involving inflammation or contracture, removal followed by tissue stabilization and reconstruction with autologous tissue may be needed.

Depending on the condition, VVLY discusses the appropriate direction together, among keeping, replacing, or removing and converting to autologous tissue. Rather than an aggressive immediate reinsertion, tissue condition is judged first, and results may vary by individual.

VVLY Signature

BESPOCO®

Bespoke + Nose — A nose that is uniquely yours

BESPOCO is VVLY's own custom rhinoplasty signature.
Rather than a one-size-fits-all implant, we analyze your facial bone structure and skin
to design a nose that exists nowhere else, using either a 3D-printed custom implant
or an autologous diced rib cartilage graft.

01
3D Custom Implant

Custom 3D Implant

After precisely scanning your nasal bone structure with a CT scan, we use an implant 3D-printed for you alone.

  • Individually made to match your nasal bone shape — reduces the chance of shifting or displacement
  • Thickness and curvature designed to match your skin thickness
  • A natural line that reduces the risk of show-through or deformation
  • Can also correct left-right asymmetry
02
Diced Rib Cartilage

Diced Rib Cartilage Graft

One natural approach that finely dices and grafts the patient's own rib cartilage. Because it is your own tissue, it feels less foreign and carries a lower burden of rejection.

  • Being your own tissue, it is stable long-term with a low burden of rejection
  • Dicing gives a natural curve and a soft feel
  • Designed to reduce the risk of contracture or deformation
  • A direction well suited to revision and contracted-nose cases
BESPOCO Process
01
Precision CT Scan
3D data of the nasal bone and surrounding structure
02
Digital Design
Optimal line design matched to your facial proportions
03
3D Printing / Processing
Custom implant fabrication, or dicing of rib cartilage
04
Precision Surgery
Performed personally by Dr. Kim Jihun, Medical Director
Surgeon
Indications

Check In If You Have Any of These Symptoms Implant-related symptoms

I.
Implant Show-Through
The skin has thinned so the implant's line shows through
II.
Shifting · Crookedness
The implant has moved, twisting the bridge or tip
III.
Shortened by Contracture
Tissue contraction has turned the nose up and shortened it
IV.
Recurring Inflammation · Redness
The nasal tip frequently reddens or shows repeated inflammation
V.
Hardness · A Foreign-Body Feeling
The area feels hard or like a foreign object when touched
VI.
Considering Conversion to Own Tissue
Wanting to remove the implant and switch to your own tissue
Procedure Steps

Implant Issues Response Process From cause diagnosis to response

01
Cause Diagnosis
Identifies and distinguishes between inflammation, contracture, shifting, and other causes.
02
Removal or Repositioning
Depending on the condition, the implant is removed or its position adjusted.
03
Reconstruction with Own Tissue
If needed, structural support is supplemented with autologous tissue.
04
Progress Observation
Recovery from inflammation and swelling is monitored together.
Surgery Information

Surgery Information Duration · recovery period · anesthesia method

Duration
About 1–3 hours (varies by scope)
Anesthesia
Sedation
Stitch Out
5–7 days after surgery
Recovery
Daily life in 1–2 weeks; swelling settles at an individual pace
Hospitalization
Same-day discharge possible (varies by case)
Materials
Removal / replacement / autologous tissue — decided per case
Before & After

Implant Issue Cases Real patient transformations

View Cases →

※ These photos are published with patients' prior consent in accordance with Korea's Medical Services Act Article 56. Results may vary by individual.

F.A.Q

Frequently Asked Questions About implant issues

Q.Does the implant always have to be removed?+
No. Depending on the cause, repositioning or replacing it can sometimes resolve the issue — this is decided after diagnosis.
Q.Will my nose look lower if it's removed?+
After removal, structural support is supplemented with autologous tissue and similar materials if needed. If immediate reconstruction is difficult, it may be done after the tissue has stabilized.
Q.There's inflammation — can revision surgery happen right away?+
If there is inflammation, stabilizing it comes first. Depending on the condition, reconstruction follows removal after a period of time.
Q.Can Gore-Tex also cause problems?+
Different materials have different characteristics, so the pattern of problems can vary — the type and condition are checked together.
Q.Why does show-through happen?+
It can occur when the skin is thin or the implant sits close to the surface. Supplementing the layer with autologous tissue is considered in that case.

Begin Your Journey The start of your transformation, now

Book a 1:1 personalized consultation at VVLY Plastic Surgery.
A board-certified plastic surgeon will personally diagnose and design your treatment.

Request Online Consultation → KakaoTalk Consultation
KakaoTalk
Consultation
Phone
Consultation
Online
Booking / Reservation
Phone KakaoTalk Chat Appointment Request